Page: 13
5.4 Install RIXs?
Up to 4 x RIX8i or RIX8+ may be installed on the system. Any Remote Input Expanders (RIXs)
installed on the Enforcer 32-WE system must be enabled in the ‘Install RIXs’ menu. For installation
details, please refer to the Installation Reference manual.
5.4.1 RIX Address
Select the address of the RIX to enable (Address 0-3).
5.4.2 RIX Installed
Enable/Disable the RIX installed. 1 = Enabled / 0 = Disabled
5.4.3 RIX Location
The location text is stored for reference on later maintenance visits i.e. “GROUND FLOOR”. For
information on how to use predictive text, please see page 5.
NOTE: We recommend if adding wired input expander RIX’s -to use the version with the PSU
integrated on board, because the Enforcer PSU might be insufficient to power multiple additional
detectors.
5.5 Program Outputs?
This option enables the programming of the outputs on the Enforcer 32-WE and any devices that are
connected.
5.5.1 Endstation PGMs?
These are the outputs on control panel itself. There are 3 outputs on the I/O module of Enforcer –
BELL PGM, STB PGM and PGM. All of them are programmable but the BELL and STB are allocated
to follow the alarm in any area as bell and strobe.
5.5.2 RIX Module PGMs?
These are the outputs that are located in the RIX8+ input expander module, if used. There are 4
PGMs located on this module.
5.5.3 ROX Module PGMs?
This option enables the addition of a wired ROX module to Enforcer as well as programming of the
PGM options for the outputs in the module.
5.5.4 Keypad PGMs?
Allows the programming of the PGM options for the outputs located on the wired keypads.
5.5.5 Reader PGMs?
Allows the programming of the PGM options for the outputs located on the wired readers.
5.5.6 User Outputs?
These outputs are used for creating automation control for Devices. The user can control them
remotely from the user menu on the keypad. The automated user outputs can be programmed
either latched or pulsed.
Polarity of the PGMs: The polarity of the outputs is normally switched negative i.e. in normal status
OFF = 0v and in active status ON = 12v.
NOTE: The PGM Outputs polarity cannot be inverted.
No. Output Type Active Restore
0000 Not Used
0001 Fire At fire alarm activation
When a valid code is entered
0002 PA Any At personal attack activation When a valid code is entered
0003 Burglary Any At burglary alarm from any area At first valid code entry
0004 Final Arm All When ALL areas are armed At code entry to disarm
0005 Open After Alarm
(Abort)
When system is silenced after ‘burglary’
alarm has been activated
After 2 minutes
0007 Tamper Any Tamper alarm in any area At code entry to silence
0008 Duress Any At a Duress alarm in any area When a valid code is entered
0009 PA Device Any At alarm on a PA input only from any
area. (This does not include the keypad
PA)
When a valid code is entered
0010 Gas At gas alarm When a valid code is entered

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals