13. Factory Defaults
ENGINEER MENU MENU DEFAULTS
DATE & TIME Year (00-99) [07]
Month (1-12) [01]
Day (1-31) [11]
Hours (0-23) [00]
Minutes (0-59) [01]
Summer Time Adjust No [0]
LEARN WIRELESS DEVICES Inputs 1 - 32 Available
Bells 1 - 2 Available
PROGRAM INPUTS Inputs 1 - 66 Unused
Input In Area A
Common Input No [0]
Input Attributes
Chime No [0]
Allow Bypass Yes [1]
Double Knock No [0]
Combined Input No [0]
Normally Open No [0]
Mask Test No [0]
Non Activity Input No [0]
Special Log No [0]
Enter number Input #
Enter Location _
INSTALL RIXs RIX Address [0]
RIX Installed No [0]
PROGRAM OUTPUTS Endstation PGMs
BELL PGM Bell Any [0014]
STB PGM Strobe Any [0016]
PGM Not Used [0000]
PGM 1 – 4 Not Used [0000]
ROX Module PGMs
ROX Installed No [0]
Keypad PGMs
PGM 1 Not Used [0000]
Reader PGMs
PGM 1 - 2 Not Used [0000]
User Outputs
User Output No [01]
User Output Type Latched [0]
Output Name _
INSTALL KEYPADS/READERS Device Address [0]
Device Type Keypad
Device Arms Area [ABCD]
Device Disarms [ABCD]
Device In Area [ABCD]
Device Name? Device 0
Enter Location _
PROGRAM TIMERS Entry Time 1 [030]
Entry Time 2 [030]
Exit Time [020]
Bell Time [03]
Bell Delay [00]
Strobe Time [00]
Number Re-Arms [3]

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals