Page: 46
14. Event Types (SIA and Contact ID codes)
Event
SIA
code
CID
code
Event
Type
Number
Default 1
(ARC)
Full Reporting
Default 2
(ARC)
No
Arm/Disarm
Default 3
(ARC)
No
Arm/Disarm
and Alarm
Restorals
Default
(SMS)
ARM
Auto Arm CA 3403 1
on
Forced Arm CF 3401 1
Arm CL 3401 1
DISARM
Disarm OP 1401 2
on
Auto Disarm OA 1403 2
(Special Arm/Disarm) ARM/DISARM WITH CODES 15 to 25
Special Disarm OP 1401 3
on
Special Arm CL 3401 3
SUBAREA / SHUNT ARM/DISARM
Sub-Area Arm CG 3402 4
on
Shunt Closed 1402 4
Sub-Area Disarm OG 1402 5
Shunt Opened 3402 5
BURGLARY ALARM
Burglary Alarm BA 1130 7
all all all once
Gas Alarm GA 1151 7
Entry/Exit alarm BA 1134 7
No Zone Activity -
Sent
NA 1680 7
24h Alarm BA 1133 7
Perimeter Alarm BA 1131 7
Keybox/Guard Zone
Alarm
1250 7
Flood Alarm WA 1154 7
Interior Alarm BA 1132 7
BURGLARY RESTORE
Burglary Restore BH 3130 9
all all
Gas Restore GH 3151 9
Entry/Exit Restore BH 3134 9
Day alarm restore BH 3133 9
Interior Alarm
Restore
BH 3132 9
Perimeter Restore BH 3131 9
Keybox Restore 3250 9
Flood Alarm Restore WH 3154 9
Ward Alarm Restore BH 3130 9
FIRE ALARM
Fire Alarm FA 1110 10
on on on on
Fire key pressed FA 1110 10
FIRE ALARM RESTORE