SC200R&SC262R_Series_Hardware_Design 110 / 124
7.7. Electrostatic Discharge
The module is not protected against electrostatic discharge (ESD) in general. Consequently, it should be
subject to ESD handling precautions that are typically applied to ESD sensitive components. Proper ESD
handling and packaging procedures must be applied throughout the processing, handling and operation
of any application that incorporates the module.
The following table shows the electrostatic discharge characteristics of SC200R series module.
Table 59: ESD Characteristics (Temperature: 25 ºC, Humidity: 45 %)
LTE-FDD B18 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
LTE-FDD B19 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
LTE-FDD B21 (10 MHz)
TBD
TBD
TBD
-96.3 dBm
LTE-FDD B26 (10 MHz)
TBD
TBD
TBD
-93.8 dBm
LTE-FDD B28 (10 MHz)
TBD
TBD
TBD
-94.8 dBm
LTE-TDD B41 (10 MHz)
TBD
TBD
TBD
-94.3 dBm
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
+/-5
+/-10
kV
All Antenna Interfaces
+/-5
+/-10
kV
Other Interfaces
+/-0.5
+/-1
kV

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel SC262R Series and is the answer not in the manual?

Quectel SC262R Series Specifications

General IconGeneral
BrandQuectel
ModelSC262R Series
CategoryControl Unit
LanguageEnglish

Related product manuals