- 13 - V-09 05/2014
Levelling mobile oven racks 20x1/1 and 20x2/1 GN
If the floor is not level, an access ramp (not sup-
plied) will be required. The incline must not
exceed 4°. pic. 1,2
Attention:
An incorrect levelled trolley can cause malfunction
during operating the unit (e. g. during Cleanjet)
Set unit legs that a height of 200 mm (7 7/8")
is reached pic. 2 "A"
Valid for SCC_WE units:
Check unit door for tightness by activating cleaning
program "rinse without tabs"
Option:
Access ramp see page 25
If there is a drain grill in front of the floor unit, a
ramp should be placed over it to enable the mobile
oven rack to be used. pic. 3
Attention:
Avoid steam sources in the ambient area of the air
filter. Sucked in humidity can cause damages and
malfunction of the unit.
Because of hygienic reason and following the
"NSF standard 4" respectively "DIN EN 203-3" all
units 20x1/1 GN respectively 20x2/1 GN must be
equipped with a cover over ball valve and
care pump. pic. 4
Cover kit and corresponding installation instruction
are delivered with the unit
1
3
4
WARNING
Hot cooking liquid
Risk of scalding
If the incline exceeds 4°, hot cooking liquid can
slop out of the cooking containers
2
A