- 17 - V-09 05/2014
The appliance must be connected to water with
drinking water quality. We recommend a maximum
water temperature of 86°F.
The appliance is to be installed with adequate back-
flow protection to comply with applicable federal,
state, and local plumbing codes.
Legend to water connections valid for:
- Table units pic. 1
1 = Common water supply 3/4”
In case of split water connection
2 = Cold water supply 3/4”
(for quenching).
3 = Treated water connection 3/4”
(steam generator, moistening, cleaning, hand
shower).
Legend to water connections valid for
- Floor units pic. 2
1 = Common water supply 3/4”
In case of split water connection
2 = Cold water supply 3/4”
(for quenching).
3 = Treated water connection 3/4”
(steam generator, moistening, cleaning, hand
shower).
For pic. 1 and pic. 2 reference items 1, 2 and 3 units
are provided with inch thread to garden hose thread
adapters (2 pieces) in starter kit.
The appliance must be connected to the facility
water supply with a supply hose that conforms to
EN 61770 resp. IEC 61770 or of similar quality.
The water supply hose must fulfil the local and/or
hygiene requirements for hoses in drinking water
systems for the respective area or municipality.
For water connection only new supply hoses may be
used. Old supply hoses must not be reused.
Install individual shut-off valve for each
appliance
Rinse the water supply line prior to connection to
the unit!
Connected water pressure must be in the range
21 - 87 psi, recommended 43 psi
Water connection
2
3
2
1
20x1/1GN - 20x2/1GN E/G
1
1
2
3
6x1/1GN - 10x2/1GN E/G
Maximum flow rate
6x1/1, 10x 1/1: 5,2 gal/min
6x2/1, 10x2/1, 20x1/1, 20x2/1: 6,6 gal/min
For filter sizing water usage can vary depending on
size and usage from 2 gal/h to 16 gal/h