- 27 - V-09 05/2014
Connection data USA/Canada
SCC_WE, CM_P Electric units:
Power kW Running Amps
6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1
2 AC 208V 11,1 53,4
2 AC 240V 11,1 61,5
3 AC 208V 11,1 22,1 19 37 38 68 30,8 61,4 52,8 102,7 105,6 189
3 AC 240V 11,1 22,1 19 37 38 68 35,5 70,8 60,9 118,6 121,8 218
3 AC 440V 11,1 22,1 19 37 38 68 14,6 29 24,9 48,6 49,9 83,9
3 AC 480V 11,1 22,1 19 37 38 68 15,8 31,5 27 52,6 54 96,7
Fuse = A AWG
6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1
2 AC 208V 60 #4
2 AC 240V 70 #4
3 AC 208V 35 70 60 125 125 200 #8 #3 #4 #2 #1 4/0
3 AC 240V 40 80 75 150 150 250 #8 #3 #4 #2 #1 3/0
3 AC 440V 20 35 30 60 60 100 #14 #8 #8 #4 #4 #2
3 AC 480V 25 40 35 70 70 110 #14 #8 #8 #4 #4 #3
SCC_WE, CM_P Gas units:
Electrical connection Power kW Running Amps
6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1
1NAC 120V 0,4 0,5 0,95 3,33 4,17 7,92
Single Phase
208V 0,4 0,77 0,5 0,8 0,95 1,6 1,92 3,7 2,4 3,85 4,57 7,69
240V 0,4 0,77 0,5 0,8 0,95 1,6 1,67 3,21 2,08 3,33 3,96 6,67
Use copper wire only for power supply connections
The maximum allowable tolerance of the supply voltage (supply voltage see
name plate) is in the range of -15% up to +10%
Note: 120V comes with 5-15P Cord & Plug
Note: 208V & 240V with 6-15P Cord & Plug

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CMP 61G and is the answer not in the manual?

Rational CMP 61G Specifications

General IconGeneral
BrandRational
ModelCMP 61G
CategoryOven
LanguageEnglish

Related product manuals