2 | Safety
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB 11 / 92
n
Do not expose the unit to weather conditions such as
rain.
n
Only connect the unit in accordance with the installation
manual and the information on the type plate.
n
Switch the unit off before disconnecting the mains
power or connecting to the mains.
n
After use, only transport the unit at ambient temperat-
ures above 0°C [32°F].
n
Only store the unit at ambient temperatures above 0°C
[32°F].
n
Do not operate the unit without an air filter.
n
Check the unit for transport damage. If you suspect the
device has been damaged in transit, contact your
dealer/freight forwarder immediately.
2.3 Safety instructions for gas appliances
Toxic exhaust fumes
Risk of asphyxiation from unauthorised concentration of
toxic exhaust fumes.
n
Ensure that the installation area can be adequately
ventilated.
n
Always perform a flue gas analysis when commission-
ing gas units.
n
If an exhaust hood is used, make sure that the exhaust
hood is switched on when operating the unit.
n
Do not put objects on the exhaust pipes.
n
Do not obstruct the area around the combustion air ex-
traction with objects.
Risk of fire due to dirty chimney
Risk of fire due to irregular cleaning of the chimney.
n
Have the chimney cleaned regularly in accordance with
the country-specific regulations.