Chapter6
The Implement Ready Power Harness is the only harness with the ISObus IBBC connector,
and should be mounted on the back of the tractor.
Best Mounting Practices
Ensure the installer follows all of the following guidelines for best mounting practices:
l
Mount the relays in fixed position on a clean, dry, easily accessible spot.
l
The red wire is positive (12V). The black wires is minus (ground). Ensure that the first
part of the red wire cannot be damaged during operation.
l
Do not tie down the extra length between the battery and the fuses, but ensure the
cable is an appropriate length. Be sure to use cable sockets with the correct size for
proper connection.
l
If a ground switch is used in the tractor, connect the wiring harness behind the ground
switch, not at the battery side of the ground switch.
l
If a main (12V) switch is used in the tractor, connect the red wire to the wiring harness
behind the main switch, not at the battery side of the main switch.
l
If no main switch is used, always connect the wiring harness directly to the battery.
l
If the system is connected to a 24V machine, always use a 24V to 12V converter. Never
connect between the two batteries of a 24V machine.
l
Tie down the harnesses so they are free from vibration and friction.
60