10 | Front Panel Overview
1.4 RCBO SAFETY SWITCH
NOTICE: When the ATS is passing through AC power from the AC Input connection, the integrated M.E.N.
connection (Main Earth Neutral - required for correct operation of the RCD) is not in circuit. The external
AC supply must provide the safety mechanism for the connected loads – consult a qualied electrician.
The RS3 Inverters are tted with an RCBO which incorporates both a residual current device as well as
a circuit breaker. The inclusion of the Type A RCBO complies with AS / NZS 4763 Standards and allows
it to be used to power xed connections of transportable structures and vehicles as per AS / NZS 3001
Standards, when installed by a licensed electrician.
Figure 4: RCBO Safety Switch
1.5 AC INPUT INTERFACE
1200 W/2000 W Models: 3000 W Models:
10 A IEC C14 Input for
connecting from AC
Grid.
16 A IEC C20 Input for
connecting from AC
Grid.
1.6 AC OUTPUT INTERFACE
1200 W/2000 W Models: 3000 W Models:
10 A IEC C13 Output
Socket for connecting
to AC appliances.
10 A GPO Outlet
Socket to plug in
appliances directly.
16 A IEC C19
Output Socket for
connecting to AC
appliances.
15 A GPO Outlet
Socket to plug in
appliances directly.