EasyManuals Logo
Home>Redarc>Inverter>RS3 Series

Redarc RS3 Series User Manual

Redarc RS3 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10 | Front Panel Overview
1.4 RCBO SAFETY SWITCH
NOTICE: When the ATS is passing through AC power from the AC Input connection, the integrated M.E.N.
connection (Main Earth Neutral - required for correct operation of the RCD) is not in circuit. The external
AC supply must provide the safety mechanism for the connected loads – consult a qualied electrician.
The RS3 Inverters are tted with an RCBO which incorporates both a residual current device as well as
a circuit breaker. The inclusion of the Type A RCBO complies with AS / NZS 4763 Standards and allows
it to be used to power xed connections of transportable structures and vehicles as per AS / NZS 3001
Standards, when installed by a licensed electrician.
Figure 4: RCBO Safety Switch
1.5 AC INPUT INTERFACE
1200 W/2000 W Models: 3000 W Models:
10 A IEC C14 Input for
connecting from AC
Grid.
16 A IEC C20 Input for
connecting from AC
Grid.
1.6 AC OUTPUT INTERFACE
1200 W/2000 W Models: 3000 W Models:
10 A IEC C13 Output
Socket for connecting
to AC appliances.
10 A GPO Outlet
Socket to plug in
appliances directly.
16 A IEC C19
Output Socket for
connecting to AC
appliances.
15 A GPO Outlet
Socket to plug in
appliances directly.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Redarc RS3 Series and is the answer not in the manual?

Redarc RS3 Series Specifications

General IconGeneral
BrandRedarc
ModelRS3 Series
CategoryInverter
LanguageEnglish

Related product manuals