RIGOL Chapter 6 MATH and Measurement
6-6 MSO1000Z/DS1000Z User’s Guide
FFT
FFT (Fast Fourier Transform) is used to transform time domain signals to frequency
domain components (frequency spectrum). MSO1000Z/DS1000Z oscilloscope
provides FFT operation function which enables users to observe the time domain
waveform and spectrum of the signal at the same time. FFT operation can facilitate
the following works:
Measure harmonic components and distortion in the system
Display the characteristics of the noise in DC power
Analyze vibration
Press MATH Math Operator to select "FFT". You can set the parameters of
FFT operation.
Figure 6-1 FFT Operation
1. Operation
Press Operation to enable or disable the FFT operation function. When FFT
operation is enabled, the time domain waveform and frequency domain
waveform are displayed separately on the screen by default as shown in
Figure
6-1. The FFT sample rate is equal to 100 divided by the current horizontal time
base in figure above.
2. Source Selection
Press Source to select the desired channel (CH1, CH2, CH3 or CH4).
3. Center Frequency
Press Center and use to adjust the frequency of the frequency domain
FFT Vertical
Scale
FFT Horizontal
Scale
FFT Sample
Rate
Time Domain
Waveform
Frequency Domain
Waveform
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Other manuals for Rigol DS1104Z Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z Plus and is the answer not in the manual?

Rigol DS1104Z Plus Specifications

General IconGeneral
BrandRigol
ModelDS1104Z Plus
CategoryTest Equipment
LanguageEnglish

Related product manuals