For digital channels:
― When 8 channels are enabled, the memory depths available include Auto,
12kPoints, 120kPoints, 1.2MPoints, 12MPoints and 24MPoints (optional).
― When 16 channels are enabled, the memory depths available include Auto,
6kPoints, 60kPoints, 600kPoints, 6MPoints and 12MPoints (optional).
Note: In "Auto" mode, the oscilloscope selects the memory depth automatically
according to the current sample rate.
Antialiasing
At slower sweep speed, the sample rate is reduced and a dedicated display algorithm
can be used to minimize the possibility of aliasing.
Press Acquire Anti-aliasing to enable or disable the antialiasing function. By
default, antialiasing is disabled and waveform aliasing is more possible.