Chapter 8 Protocol Decoding RIGOL
MSO1000Z/DS1000Z User’s Guide 8-5
Press Width to enable or disable the width display function. When "ON" is
selected, the current bus width will be displayed on the right side of the
format display (the bus display is turned on). You can use "Width" to set the
bus width.
Dig.Sa menu displays the current digital sample rate which relates to the
data source selected currently. When the data source is "Trace", the digital
sample rate relates to the horizontal time base.
Note: By default, MSO1000Z/DS1000Z uses "Trace" as the data source.
12. Event Table
The event table displays the decoded data and the corresponding line number
and time in table format. It can be used to observe relatively longer decoded
data. Press Evt.Table EventTable to select "ON" (Note: This operation is
only available when MATH Decode1 / Decode2 Decode is set to "ON")
to enter the event table interface as shown in Figure 8-2.
Format: set "Data" display format in the event table to HEX, DEC or ASC.
Focus: press this key and turn to browse the "Data" item.
View: select the display form of the event table. If "Packets" is selected, the
time and data are displayed in the event table; if "Details" is selected, the
detailed data of the specified row will be displayed in the event table; if
"Payload" is selected, all data of the specified column will be displayed in the
event table. When different view is selected, the export format of the data table
will change accordingly.
Data: select the data column to be viewed in the "Details" or "Payload" view. It
is valid for the decoder of multiple data output.
Order: select the display type of decoding result in the event table to "Ascend"
or "Descend".
Export: if a USB storage device (FAT32 format, flash memory) is currently
connected to the instrument, press this softkey to export the data table to the
external USB storage device in CSV format ("Packets" is selected) or HEX format
("Payload" or "Details" is selected).
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Other manuals for Rigol DS1104Z-S Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z-S Plus and is the answer not in the manual?

Rigol DS1104Z-S Plus Specifications

General IconGeneral
BrandRigol
ModelDS1104Z-S Plus
CategoryTest Equipment
LanguageEnglish

Related product manuals