RIGOL Chapter 6 Operations and Measurements
6-12 MSO7000/DS7000 User Guide
âš« Press SourceA and SourceB respectively, and rotate the multifunction knob
to select the channel for Source A and Source B. Then press down the knob
to select the channel. You can also press SourceA and SourceB continuously
or enable the touch screen to select the channel. The available channels for
Source A and Source B are CH1-CH4 and D0-D15.
Note: Only the channels that have been enabled currently can be selected.
➢ If Source A (or Source B) selects CH1, press More → Thre.CH1 to set the
threshold of Source A (or Source B) in logic operation. For setting methods,
refer to descriptions in "Parameter Setting Method".
➢ If Source A (or Source B) selects CH2, press More → Thre.CH2 to set the
threshold of Source A (or Source B) in logic operation. For setting methods,
refer to descriptions in "Parameter Setting Method".
➢ If Source A (or Source B) selects CH3, press More → Thre.CH3 to set the
threshold of Source A (or Source B) in logic operation. For setting methods,
refer to descriptions in "Parameter Setting Method".
➢ If Source A (or Source B) selects CH4, press More → Thre.CH4 to set the
threshold of Source A (or Source B) in logic operation. For setting methods,
refer to descriptions in "Parameter Setting Method".
âš« Press Offset, and then rotate the multifunction knob to adjust the vertical
offset of the operation results. You can also directly rotate Wave Vertical
POSITION or enable the touch screen to adjust the vertical offset.
âš« Press Size, and then rotate the multifunction knob to select the waveform
size. Press down the knob to select it. You can also press Size continuously or
enable the touch screen to select it. The available sizes include "Small",
"Medium", and "Large". Also, you can rotate Wave Vertical SCALE to
adjust the waveform size.
⚫ Press More → AutoSetting to adjust the vertical scale and offset of the
operation results to the optimal value according to the current configuration, so
as to better observe.
⚫ Press More → Sensitivity to set the sensitivity of the digital signal converted
from the analog signal on the source. For setting methods, refer to descriptions
in "Parameter Setting Method".
⚫ Press More → Label to set the label for math operation results. For details,
refer to descriptions in "Math Operation Label".
"XOR" Operation
Performs logic "XOR" operation on the waveform voltage values of the specified
sources point by point and displays the results. In operation, when the voltage value
of the source channel is greater than the threshold of the corresponding channel, it is
regarded as logic "1"; otherwise it is logic "0". The results of logic XOR operation of

Table of Contents

Other manuals for Rigol DS7024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS7024 and is the answer not in the manual?

Rigol DS7024 Specifications

General IconGeneral
BrandRigol
ModelDS7024
CategoryTest Equipment
LanguageEnglish

Related product manuals