Linear ue installation guide 13541-A 01-20 | 5
2° fall to the horizontal ue
terminal
There must be a continuous fall of at least 2° to
the horizontal wall termination. This is so any
rain water exits the ue naturally.
fall
Flue terminal locations Flue terminals must be compliant with the ue terminal locations
shown in AS/NZS 5601.1.
The ue terminal must be positioned away from any
ammable materials.
Keep snow and other items, such as outdoor furniture well
clear of the ue terminal at all times.
DO NOTDO NOT DO NOT DO NOT
Do not ue into
natural draught
ues or replaces.
Do not ue into
other rooms.
Do not ue into
roof spaces.
Do not ue
under oor
spaces.
To ensure products of combustion
are cleared, adequate clearance
from the building is required. The
vertical cowl should have a
500 mm clearance from any part
of the building. This also applies to
steeped and pitched roofs, where
the ue cowl should be 500 mm
clear of the ridge line.
An adequate ow of fresh air must
exist around the ue cowl following
installation.
Minimum clearances are shown in AS/NZS 5601.1.
500 mm to
nearest
part of the
roof

Other manuals for Rinnai Linear Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Linear Series and is the answer not in the manual?

Rinnai Linear Series Specifications

General IconGeneral
BrandRinnai
ModelLinear Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals