Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.
PROBLEM SOLUTION
The air conditioner does
not work at all.
• Checkpowerstatusandthenoperatetheairconditioneragain.
• Pluginorswitchonthecircuitbreakerandthenoperatetheairconditioneragain.
• CheckifyouhavesettheOTimer.Operatetheairconditioneragainbypressingthe
Power button.
The temperature
adjustment is not working.
• CheckifyouhaveselectedFan/Turbomode.Inthesemodes,desiredtemperatureissetto
auto and you cannot adjust the temperature.
Cool/Warm air does
not come out of the air
conditioner.
• Checkifthesettemperatureishigher(duringCoolmode)/lower(duringHeatmode)than
the current temperature. Press the Temp + or - button on the remote controller to change
the set temperature.
• CheckiftheAirlterisblockedbydirt.IfthereisalotofdustontheAirlter,
cooling(heating) performance may decrease. Clean them frequently.
• Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle.Takethecoveroand
take the obstacle away.
• Ifyouwanttooperatetheairconditionerinthesunlight,covertheoutdoorunitusing
curtains or etc.
• CheckiftheairconditionerisoperatinginDe-icemode.Whentheiceformedinwinter
or the outdoor temperature is too low, the air conditioner operates in De-ice mode
automatically. In De-ice mode, indoor fan stops and cool air does not come out.
• Ifthedoorsorwindowsareopen,itmaycausebadcooling(heating)performance.
Close the doors and windows.
• Checkiftheairconditionerhasjustbeenturnedonafterstoppingcoolingorheating
operation. In this case, just a fan will run to protect the outdoor unit compressor.
• Checkifthepipelengthistoolong.Whenthepipelengthexceedsmaximumallowable
pipe length, cooling (heating) performance may decrease.
Air ow adjustment is not
working.
• CheckifyouhaveselectedAuto/Dry/
mode. In these modes, desired
temperature is set to auto and you cannot adjust the temperature.
Fan speed adjustment is
not working.
• Check if you have selected Auto/Dry/Turbo/
mode. In these mode, fan speed
is set to Auto and you cannot adjust the fan speed.
Remote controller is not
working.
• Checkifyourbatteriesaredepleted.
• Makesurenothingisblockingyourremotecontrollersensor.
• Checkthattherearestronglightingapparatusneartheairconditioner.Stronglightwhich
comes from uorescent bulbs or neon signs may interrupt the electric waves.
Timer function does not
set.
• CheckifyoupresstheSet button on the remote controller after you have set the time.
The indicator is blinking
continuously.
• PressthePower
button or disconnect the power plug/switch o the auxiliary power
switch.
If the indicator is still blinking, contact the service center.
Odors permeate in the
room during operation.
• Checkiftheapplianceisrunninginasmokyarea.Ventilatetheroomoroperatetheair
conditioner in Fan mode for 1~2 hours. (We do not use smelly components in the air
conditioner.)
Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 20 2011-3-19 10:07:54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung AQ09UGFN and is the answer not in the manual?

Samsung AQ09UGFN Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor unit weight7800 g
Indoor units quantity1
Indoor unit dimensions (WxDxH)820 x 190 x 285 mm
TypeSplit system
Remotely operatedYes
Refrigerating mediumR410A
Cooling capacity (max)9384 BTU/h
Dehumidifying capacity1 l/h
Heating capacity (max)9896 BTU/h
Air conditioner functionscooling, dehumidifying, heating
Cooling capacity in watts (max)2750 W
Heating capacity in watts (max)2900 W
Cooling energy efficiency (EER, W/W)3.22
Heating energy efficiency (COP, W/W)3.61
Airflow7.5 m³/h
Outdoor units quantity0
Noise level (low speed)24 dB
Noise level (high speed)32 dB
Power requirementsAC 220 - 240 V, 50 Hz
Annual energy consumption428 kWh
Power consumption (cooling) (max)855 W
Power consumption (heating) (max)803 W