7 TROUBLESHOOTING COD: 60S12/24.B.2021
EN
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
41
7. TROUBLESHOOTING
7.1 Troubleshooting chart
Issue
Cause
Remedy
Pump doesn’t start
Electronic issue
Activate the by-pass
Pump starts but the system
suddenly blocks in high pressure
Hydraulic block
Dirty filters
Obstruct membranes
Commutation system block
Perform reset procedure
Replace filters
Perform washing procedure
Contact a customer service
During operation, the pump
temporarily switches off, giving
rise to a start and stop
phenomenon
Dirty filters or membranes
Clean or replace
Metal noise of the pump
Pump cavitation
Check the causes of the absence
of water flow at the pre-pump inlet
Low production / normal or low
pressure
Low battery
Air within the system
Loss of sealing systems
Check battery charge
Purge the air out of the system
Contact a customer service
Low production / high pressure
(> 13 Bar)
Clogged filters
Clogged membranes
Cold inlet water
Replace filters
Perform washing procedure
Contact a customer service
Loss in the system
Loose fittings
ERS leaks
Tighten fittings
Contact a customer service

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenker SMART 60 and is the answer not in the manual?

Schenker SMART 60 Specifications

General IconGeneral
BrandSchenker
ModelSMART 60
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals