7. PARAMETER SETTING VM-5S
-56-
7-14 MONITOR OUTPUT / PULSE OUTPUT SELECTION
(1) Remove the monitor unit from the rack.
Refer to the instruction manual of the instrument rack in which the monitor is
installed.
(2) The jumper pins for selecting between monitor and pulse output are located in the center of the
main board.
Connect the jumper to obtain the desired output (PUL or BUF).
PUL The internally shaped pulse signal is output through a buffer amplifier.
BUF The input signal from the sensor is output through a buffer amplifier.
Do not touch any parts not specifically mentioned.
(3) After verifying the set value, reinstall the monitor unit in the rack.
Refer to the instruction manual of the instrument rack in which the monitor is
installed.
Mandatory
Mandatory
Mandatory
VM-5
TRIGGER
CARD
PUL2
PUL1
BUF1
BUF2
J505
CH2
CH1
J305
Detail
CONNECTOR