Chapter 1
Introduction
RUGGEDCOM RST2228
Installation Guide
4 Required Tools and Materials
LED State Description
Off No active alarm conditions exist
Solid The power source is supplying power to the devicePS1/PS2
Off The power source is not supplying power to the device
USB Console Port The serial console port is for interfacing directly with the device and accessing initial
management functions. For information about connecting to the device via the serial
console port, refer to Section3.1, “Connecting to the Device”.
Alarm Indicator LED The alarm indicator LED illuminates when an alarm condition exists. Pressing the Alarm Cut-
Off (ACO) button clears the alarm(s).
Removable Media The device features sockets for up to four SFP/SFP+ transceivers and slots for up to six
removable media modules. For more information, refer to Chapter4, Communication Ports.
Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs. For more
information, refer to:
Section2.4, “Connecting the Failsafe Alarm Relay”
Section5.2, “Failsafe Alarm Relay Specifications”
Power Supply Terminal Block A pluggable terminal block. For more information, refer to:
Section2.5, “Connecting Power”
Section5.1, “Power Supply Specifications”
Chassis Ground Terminal Protects the device from power surges and accumulated static electricity. For information
about grounding the device, refer to Section2.5, “Connecting Power”.
Section1.3
Required Tools and Materials
The following tools and materials are required to install the RUGGEDCOM RST2228:
Tools/Materials Purpose
AC/DC power cord For connecting power to the device. For the required. To determine
the proper wire gage, refer to Section5.1, “Power Supply
Specifications”.
Lightning protector For protecting the device from harmful electrical strikes.
Flathead screwdriver For removing or installing modules and terminal blocks.
Torx T10 screwdriver For removing or installing modules.
Phillips screwdriver For removing or installing terminal blocks.
8 x M6 or #10-32 screws For mounting the device to a panel.
8 x M6 or #10-32 screws For mounting the device to a rack.
Braided or equivalent ground wire For grounding the device to safety Earth.