34 Installing/Removing Line Modules
RUGGEDCOM RX1500PN LM Blank Specifications
Article Numbers
6GK6015-0AL20-0AA0
(Standard)
6GK6015-0AL20-0AA1
(Conformal Coated)
Section4.2
Installing/Removing Line Modules
Upon installing a new line module in the device, all features associated with the module are available in
RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM
RX1501.
Once a line module is removed, all the features associated with the module are hidden or disabled in RUGGEDCOM
ROX II.
CAUTION!
Electrical hazard – risk of power failure. Do not install more than two RUGGEDCOM APE modules.
Installing more than two of this type of module can lead to power fluctuations and irregular shut
downs.
IMPORTANT!
Only one WAN line module is supported per chassis.
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty and open
ports are protected with plugs or covers.
Removing a Module
To remove a line module, do the following:
1. [Optional] If the device is installed in a rack, remove it from the rack.
2. Loosen the screws that secure the module.
3. Pull the module from the chassis to disconnect it.

Other manuals for Siemens RUGGEDCOM RX1501

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RX1501 and is the answer not in the manual?

Siemens RUGGEDCOM RX1501 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RX1501
CategorySwitch
LanguageEnglish

Related product manuals