Technical Specifications
B-2
SIMATIC Field PG Manual
A5E00075760-04
General
Dimensions (w x h x d) 328 x 294 x 52 mm
Weight approx. 4 kg
Line voltage external power supply 100 VAC to 240 VAC (+ 10% / – 15%)
Line voltage frequency 50 / 60 Hz (47 to 63 Hz)
Brief voltage interruption acc. to Namur > 20 ms at 93 V (AC power supply)
(max. 10 times per hour; min. recovery time 1 s)
Max. power consumption
Output DC voltage (external power supply)
Output DC current (external power supply)
Output DC power (external power supply)
Standby power ( battery operation)
Lithium Ion rechargeable battery (9 cells)
with charge-status monitoring
90 W
16 V
max. 4.5 A
max. 72 W
approx. 4.8 Ah, 10.8V with thermostatic switch and multi-
fuse, recyclable, chargeable up to 40C (108 F), high num-
ber of charge cycles under severe conditions, low self-di-
scharge rate
Degree of protection IP30 (covers closed)
Quality assurance ISO 9001
Safety
Requirements VDE 0805 ^ EN 60950 and IEC 60950
Protection class I to IEC 60536
Protective separation between supply and secondary circuit
(via external power supply)
Noise emission <45 dB(A) to DIN 45635
Electromagnetic compatibility (EMC)
Emitted interference limit value class B to EN 55022, EN 6100–3–2,
Line-fed interference on AC supply lines 2 kV (IEC 61000-4-4; burst)
1 kV (IEC 61000-4-5; s pulse/line to line)
2 kV (IEC 61000-4-5; s pulse/line to ground)
Noise immunity on signal lines 2 kV (IEC 61000-4-4; burst; length >3 m)
2 kV (IEC 61000-4-5; s pulse/line to ground;
length > 20 m)
Noise immunity to discharges of static
electricity
4kV, Contact discharge (IEC 61000-4-2; ESD)
8kV, Air discharge (IEC 61000-4-2; ESD)
Immunity to RF interference 10 V/m, with 80% amplitude modulation at 1 kHz,
9 kHz - 80 MHz (to IEC 61000-4-6)
10 V/m with 80% amplitude modulation at 1 kHz,
80 kHz - 1GHz (to IEC 61000-4-3)
10 V/m, pulse modulated 50% duty cycle, 900MHz and
1,89 GHz (to IEC 61000-4-3)
Magnetic field 30 A/m, 50Hz (to IEC 61000-4-8)