CP 1604 / CP 1616
Operating Instructions, 02/2017, C70000-G8976-C218-08
35
Operating hardware
4
4.1
Diagnostics with SNMP
4.1.1
SNMP and CP 1616/CP 1604
Diagnostics with SNMP
Using SNMP (Simple Network Management Protocol), a network management station can
configure and monitor SNMP-compliant devices. To allow this, a management agent is
installed on the device with which the management station exchanges data using Get and
Set requests.
MIB
A MIB (Management Information Base) is a type of database containing the description of
the objects and functions of a device. SNMP clients access this information.
A distinction is made between standardized and private MIBs:
Standardized MIBs are described in RFC documents.
Private MIBs contain product-specific expansions.
MIB II describes a set of SNMP variables that is normally supported by all SNMP-compliant
devices.
SNMP V1 and SNMP V2 protocols
With the SNMP V1 and SNMP V2 protocols, all the objects of MIB-II relevant for the product
and the objects of a private MIB can be queried.
SNMP-compliance of a CP 1616/CP 1604
A management agent is integrated in the CP 1616/CP 1604.
The CP 1616/CP 1604 supports the SNMP V1 and SNMP V2 protocols.
In the MIB-II, the CP 1616/CP 1604 contains all groups except "egp and transmission" and
"at".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET CP 1604 and is the answer not in the manual?

Siemens SIMATIC NET CP 1604 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET CP 1604
CategoryController
LanguageEnglish

Related product manuals