PLC Subroutines Manual
44 6FC5397-0FP40-0BA0, 08/2013
Local variable definition
Table 3-9 Inputs
DELAY WORD Spindle braking duration (unit: 0.1 s)
DrvEn BOOL Drive enable
SP_EN BOOL Spindle action condition (1: allowed; 0: not allowed)
IsBrake BOOL Spindle braking function (1: enabled; 0: forbidden)
Table 3-10 Outputs
SP_brake BOOL Spindle braking output
SP_LED BOOL Spindle running state
Assigned global variables
SP_B_CMD BOOL Spindle braking command
T11 TIMER Spindle braking timer
Relevant PLC machine data
14510 [13] BOOL Spindle braking duration (unit: 0.1 s)
14512 [19].1 BOOL Selection of spindle braking function (1: enabled; 0: forbidden)
Example for calling subroutine 42
Subroutine 43 - MEAS_JOG (measurement in the JOG mode)
Purpose
Subroutine 43 is used to process the information from the measuring probe and to realize the "measuring in the JOG mode"
function. You can use this subroutine to calibrate the probe and measure a tool.
The precondition for calling this subroutine is to call subroutine MCP_NCK (SBR38) in the main program. The "measuring in
the JOG mode" function is automatically deactivated if you have changed the operating mode when the function becomes
active.
Local variable definition
Table 3-11 Inputs
Meas_Enable BOOL Activating the function of "measuring in JOG mode"