Table 3-44 Outputs
Ko_1…Ko_8 BOOL Output of switch 1...output of switch 8
Assigned global variables
K1st1 … K8st1 MB245 State 1 of the hold switch
K1st2 … K8st2 MB246 State 2 of the hold switch
K1on … K8on MB247 "On" state of the hold switch
Relevant PLC machine data
None
Example for calling subroutine 63
Use of user alarms in the PLC subroutines
Some user alarms are activated in a subroutine. In the case that such an alarm is generated, you can search the following
list for the subroutine wherein the alarm is activated.
700010 DB1600.DBX1.2 HHU is active SBR41: MINI_HHU
700011 DB1600.DBX1.3 Not able to lock tool in expected time
700012 DB1600.DBX1.4 Spindle in braking progress SBR42: SPINDLE
700013 DB1600.DBX1.5 Operation while chuck is not locked SBR56: Lock_unlock_T
700014 DB1600.DBX1.6 Gear-change time out SBR49: GearChg1_Auto
700015 DB1600.DBX1.7 Gear level position error
700016 DB1600.DBX2.0 Drives not ready SBR33: EMG_STOP
700017 DB1600.DBX2.1 Operate chuck when spindle or part program is
running
SBR56: Lock_unlock_T
700018 DB1600.DBX2.2 Cooling motor overload SBR44: COOLING
700019 DB1600.DBX2.3 Coolant liquid position in low level
700020 DB1600.DBX2.4 Lubrication motor overload SBR45: LUBRICAT
700021 DB1600.DBX2.5 Lubricant liquid position in low level
700022 DB1600.DBX2.6 Turret motor overload SBR51: Turret1_HED_T