Introduction
2
2.1 Checklist SINUMERIK Integrate 5.x
Before you install the SINUMERIK Integrate 5.x server, observe and check the following points:
Overview
You require administrator rights to install on the server: Authorization level, user
"Administrator" as "Domain User".
On the SQL server, you require authorization level user "Sysadmin" as "Domain User".
- OR -
You have authorization level user "dbcreator" and "securityadmin".
Database "DB Instance" is available. A basic database, without a database instance, is not
sufficient.
The database should either be available on the local computer or on a separate server
and must be able to be accessed by the server.
SQL server and SINUMERIK Integrate 5.x server communicate via port 1433.
Check that this requirement is fulfilled on the application server using the following
PowerShell command: Test-NetConnection [SQL-IP] -port 1433
Check the firewall settings.
- OR -
Check the group policy with your IT department.
The application server (SINUMERIK Integrate server) communicates with the SINUMERIK
controller via port 8090 (HTTP).
Check that this requirement is fulfilled on the application server using the following
PowerShell command: NetConnection [APPSRV-IP] -port 8090
Check the firewall settings.
- OR -
Check the group policy with your IT department.
The application server communicates with the license server via port 2800 (default)
The defined port should be enabled between the application server and license server.
The default port is defined when installing the license server.
Check that this requirement is fulfilled on the application server using the following
PowerShell command: Test-NetConnection [LICSRV-IP] -port [LICSRV-
PORT]
Maintenance is not activated - program maintenance checks various times, especially the
rights before and during the installation.
The automatic Windows maintenance significantly slows down the setup process.
Therefore, deactivate the maintenance function while you execute setup.
IIS service runs
Manage MyResources, Optimize MyProgramming /NX-Cam Editor
Installation Manual, 12/2019, A5E44672080B AE 13

Table of Contents

Other manuals for Siemens SINUMERIK 840DE SL

Questions and Answers:

Siemens SINUMERIK 840DE SL Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840DE SL
CategoryControl Systems
LanguageEnglish

Related product manuals