No.PS※※-OMM0007-H
M8 (3 pin) connector
Wiring of connector
Connections should only be made with the power supply turned off.
Tighten the connector by hand.
Use separate routes for the pressure sensor wiring and any power or high voltage wiring. Otherwise,
malfunction may result due to noise.
1
DC(+)
3
DC(-)
4
OUT
Internal circuit and wiring example
Z/ISE40A- - - L
Output specification
-N
NPN open collector output type
Max. 28 V, 80 mA
Residual voltage 1 V or less
-P
PNP open collector output type
Max. 80 mA
Residual voltage 1 V or less
: The lead wire with connector is not included with the product. (Refer to page 11)