-37-
No.PS※※-OMM0007-H
Press the button to set.
Setting of [F 5] Analogue output / Auto-shift input completed
Conditions and explanations for auto-shift function
•Maintain a constant pressure for 5 ms or longer from the end of the auto-shift input signal.
•At auto-shift input, [ooo] is displayed for approximate 1 second. The measured pressure value at that time
is stored as the corrected value [C_5].
•With the corrected value stored, the set value is compensated.
•The switch output will start within 10 ms of the auto-shift input signal.
•If the measured pressure exceeds the set pressure range during auto-shift input signal, the corrected
value will not be stored and [o.r] is displayed for approximately 1 second.
•If the pressure is within the set pressure range and beyond the set value corrected by auto-shift (including
hysteresis) when the auto-shift input is applied, the set value is corrected to the upper limit or lower limit
(whichever is closer) of the set pressure range automatically. (The correction is performed when the
auto-shift input is applied at the pressure beyond the set pressure range. If the auto-shift input is applied
again at the pressure within the set pressure range, the correction is released and the product operates
according to the set value).
•After completing the pressure setting of OUT2, the corrected value and [C_5] will be displayed in turn.
Press the button to return to measurement mode.
•The corrected value [C_5] after auto-shift input will disappear when the power is turned off, and will reset
to zero (initial value) when the power is returned.
: The EEPROM is not used for the memory corrected value.
Using the Auto-shift input, the acceptable set range is as follows: