physical location of each power optimizer, as described in
Creating Logical and
Physical Layout using Installation Information
on page 57.
Step 4: Verifying Proper Power Optimizer Connection
When a module is connected to a power optimizer, the power optimizer outputs a safe
voltage of 1V (±0.1V). Therefore, the total string voltage should equal 1V times the
number of power optimizers connected in series in the string. For example, if 10 power
optimizers are connected in a string, then 10V should be produced.
Make sure the PV modules are exposed to sunlight during this process. The power
optimizer will only turn ON if the PVmodule provides at least 2W.
In SolarEdge systems, due to the introduction of power optimizers between the PV
modules and the inverter, the short circuit current I
SC
and the open circuit voltage V
OC
hold different meanings from those in traditional systems.
For more information about the SolarEdge systems string voltage and
current, refer to the
V
OC
and I
SC
in SolarEdge Systems Technical Note
,
available on the SolarEdge website at:
https://www.solaredge.com/sites/default/files/isc_and_voc_in_solaredge_
sytems_technical_note.pdf
To verify proper power optimizer connection:
Measure the voltage of each string individually before connecting it to the other
strings or to the inverter. Verify correct polarity by measuring the string polarity with
a voltmeter. Use a voltmeter with at least 0.1V measurement accuracy.
NOTE
Since the inverter is not yet operating, you may measure the string voltage
and verify correct polarity on the DC wires .
For troubleshooting power optimizer operation problems, refer to
Power Optimizer
Troubleshooting
on page 62.
Proper power optimizer connection can also be verified in the Designer application.
For more information, refer to
https://www.solaredge.com/products/installer-tools/designer#/.
StorEdge Three Phase Inverter MAN-01-00648-1.3
20 Step 4: Verifying Proper Power Optimizer Connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge StorEdge SE5K-RWS and is the answer not in the manual?

SolarEdge StorEdge SE5K-RWS Specifications

General IconGeneral
BrandSolarEdge
ModelStorEdge SE5K-RWS
CategoryInverter
LanguageEnglish

Related product manuals