Play Device? 1 to 12, FrameMemory1Clip to
FrameMemory20Clip
Target device
Mode? Normal (a),
Recue (b),
Loop (c)
Playback mode
(a): Normal mode
For FrameMemory1Clip to
FrameMemory20Clip, settings are ignored and
operation mode is fixed to “Normal.
(b): Recue mode
(c): Loop mode
Cue Device? 1 to 12, FrameMemory1Clip to
FrameMemory20Clip
Target device
Timecode? Current (a),
hh:mm:ss:ff
Start point timecode
hh=hours (00 to 23)
For FrameMemory1Clip to
FrameMemory20Clip, “hh” is fixed to “01.
mm=minutes (00 to 59)
ss=seconds (00 to 59)
ff=frames (00 to 29)
(a): Mode in which the currently set timecode is
used
Stop Device? 1 to 12, FrameMemory1Clip to
FrameMemory20Clip
Target device
FF Device? 1 to 12, FrameMemory1Clip to
FrameMemory20Clip
Target device
Rewind Device? 1 to 12, FrameMemory1Clip to
FrameMemory20Clip
Target device
DiskFileLoad Device? 1 to 12 Target device
FileName? Filename Name of file (max. 23 characters)
DiskFolderSet Device? 1 to 12 Target device
FolderName? Foldername Name of folder (max. 23 characters)
Snapshot Region? ME1 to ME5, PP, User1 to
User8, DME1 to DME4,
Router
Target region
Register? 1 to 99 Target register number
Attribute? Off, Dissolve, AutoTransition,
Dissolve&AutoTransition
Target snapshot attribute
Time? Current (a) Duration of effect dissolve
(a): Mode in which the currently set value is
used
The target to set is “Current” only, and cannot
be changed.
KeySnapshot ME? ME1 to ME5, PP Target control block
Key? Key1 to Key8 Target key
Register? 1 to 4 Target register number
WipeSnapshot ME? ME1 to ME5, PP Target control block
Register? 1 to 10 Target register number
DMEWipeSnapshot ME? ME1 to ME5, PP Target control block
Register? 1 to 10 Target register number
TimelineRecall Region? ME1 to ME5, PP, User1 to
User8, DME1 to DME4, PBus,
Device1 to Device12, GPI
Target region
Register? 1 to 399 Target register number
Symbol Parameter name Arguments Description

Table of Contents

Other manuals for Sony ICP-X7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony ICP-X7000 and is the answer not in the manual?

Sony ICP-X7000 Specifications

General IconGeneral
BrandSony
ModelICP-X7000
CategorySwitch
LanguageEnglish

Related product manuals