8.2.2 Description of parameters
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Proportional band 1
(For output 1)
Range:0.0~200.0%
ON/OFF control if set to 0 (0.0)
Reserved
Auto tuning offset value
Output 1 cycle time
Hysteresis for output 1
ON/OFF control
Proportional band 2
(For output 2)
Integral time 2
(For output 2)
Derivative time 2
(For output 2)
Output 2 Cycle time
Hysteresis for output 2
ON/OFF control
Control gap 1
(For output 1)
Control gap 2
(For output 2)
Function lock
Range:0~3600 seconds
PD control if set to 0
Range:0~900 seconds
PI control if set to 0
Reserved
Range:0~USPL
Range:0~150 seconds
Relay output : 10
Voltage pulse output : 1 , mA output: 0
Range:0~1000
The same with P1
The same with I1
The same with D1
The same with CYT1
The same with HYS1
Set point of output 1 (Heating side)
=SV - GAP1
=SV + GAP2
Return to “P1"
If P2=0.0
Display
Display if output2 is provided
Integral time 1
(For output 1)
Derivative time 1
(For output 1)
If P1=0.0
Display
Levels entering available
LCK
Level 1
(User)
Level 2
(PID)
Level 3
(Input)
Level 4
(SET)
Parameters which can be
changed
------ All parameters (default value)
------ All parameters
------ ------ All parameters except level 3
------ ------ Parameters in level 1
------ ------ “SV” and “LCK”
------ ------ Only “LCK”