Save and Recall I
nformation
7. Push the Menu Off button to cancel the
save operation, or push a side-bezel menu
OK Save item to
complete the operation.
OK Save
Saving a Screen Image
A screen image consists of a graphical image of the oscilloscope screen. This is different from waveform data, which
consists of numeric values for each poi nt in the waveform. To save a screen image:
1. Push Save / Recall Menu .
2. Push Save Screen Image from the
lower-bezel menu.
Save
Screen
Image
Save
Waveform
Save
Setup
Recall
Waveform
Recall
Setup
Assign
Save|to
Setup
File
Utilities
Save
Screen
Image
3. From the side-bezel menu, push File
Format repeatedly to select .tif, .bmp, and
.png formats.
File
Format
.png
4. Push Ink Saver to turn the Ink Saver mode
on or off. When on, this mode provides a
white background.
Ink Saver
On |
Off
5. Push Edit File Name to create a custom
name for the screen image le. Skip this
step to use a default name.
Edit File
Name
6. Push OK Save Screen Image to write the
image to the selected media.
OK Save
Screen
Image
For information on printing screen images of waveforms, go to Printing a Hard Copy. (See page 120, Printing a Hard Copy.)
MSO2000B and DPO2000B Series Oscilloscopes User Manual 113

Table of Contents

Other manuals for Tektronix DPO2024B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2024B and is the answer not in the manual?

Tektronix DPO2024B Specifications

General IconGeneral
BrandTektronix
ModelDPO2024B
CategoryTest Equipment
LanguageEnglish

Related product manuals