Commands Listed in Alphabetical Order
NOTE. The DC lev
el is controlled by AFG:OFFSet.
Conditions
MDO3000 series with option MDO3AFG installed and MDO4000C series with
option MDO4A
FG installed only.
Group
AFG
Syntax
AFG:FUNCtion
{SINE|SQUare|PULSe|RAMP|NOISe|DC|SINC| GAUSsian|LORENtz
|ERISe|EDECAy|HAVERSINe|CARDIac|ARBitr ary}
AFG:FUNCtion?
Arguments
SINE
SQUare
PULSe
RAMP
NOISe
DC – The DC level is controlled by AFG:OFFSet.
SINC (Sin(x)/x)
GAUSsian
LORENtz
ERISe
EDECAy
HAVERSINe
CARDIac
ARBitrary
Examples
AFG:FUNC LOREN specifies to generate the Lorentz function.
AFG:HIGHLevel
This command sets (or queries) the high level value of the output waveform, in
volts, when using the arbitrary function generator feature. The high levelvalue
is constrained by the requirements for amplitude and offset; updating thisvalue
changes the amplitude and offset values.
2-132 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual