Command Groups
Table 2-19: Calibration and Diagnostic Commands (cont.)
Command
Description
CALibrate:RESults:FACtory:SCOPE? This query returns the factory calibration status for the oscilloscope (doesn't include RF or
AFG) of the instrument.
CALibrate:RESults:SPC? Returns the results of the last SPC operation.
CALibrate:RESults:SPC:RF? This query returns the status of the last SPC run for the RF portion of the
instrument (doesn't include analog channels) . This query is synonymous with
CALibrate:INTERNal:STATus:R F?
Available on mixed domain oscilloscope models with RF enabled.
CALibrate:RESults:SPC:SCOPE? This query returns the status of the last SPC run for the oscilloscope portion of
the instrument (doesn't include the RF portion). This query is s ynonymous to
CALibrate:INTERNal:STATus:S COPE?
CALibrate:RF
This command begins the RF calibration process.
Available on mixed domain oscilloscope models with RF enabled.
CALibrate:RF:STARt
This command is identical to
CALIBRATE:RF.
Available on mixed domain oscilloscope models with RF enabled.
CALibrate:RF:STATus? This query returns the s tatus of the last RF calibration.
Available on mixed domain oscilloscope models with RF enabled.
DIAg:LOOP:OPTion Sets the self-test loop option.
DIAg:LOOP:OPTion:NTIMes Sets the self-test loop option to r un N times.
DIAg:LOOP:STOP Stops the self-test at the end of the current loop.
DIAg:RESUlt:FLAg? Returns the pass/fail status from the last self-test sequence execution.
DIAg:RESUlt:LOG? Returns the internal results log from the last self-test sequence execution.
DIAg:SELect Runs self tests on the specied system subsystem.
DIAg:SELect:<function> Species which of the subsystems will be tested when the DIAg:STATE EXECute
command is run.
DIAg:STATE Sets the oscilloscope operating state.
Conguration Command Group
Use the queries in the Configuration Command Group to determine whether a
particular feature is present.
Table 2-20: Conguration Commands
Command
Description
CONFIGuration:ADVMATH?
This query returns a boolean value to indicate whether the
instrument supports the advanced math feature.
CONFIGuration:AFG? Indicates whether or not the arbitrary function generator
hardware is present, and the arbitrary function generation feature
is enabled.
CONFIGuration:ANALOg:BANDWidth? This query returns the maximum bandwidth for analog channels.
2-20 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO3000 Series and is the answer not in the manual?

Tektronix MDO3000 Series Specifications

General IconGeneral
BrandTektronix
ModelMDO3000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals