Commands Listed in Alphabetical Order
Syntax
MASK:LOCk {ON|
OFF|<NR1>}
MASK:LOCk?
Related Commands
MASK:SOUrce
Arguments
ON turnsonthisfeature,sothatthemask is locked to the waveform.
OFF turns off this feature.
<NR1> = 0 turns off this feature. Any other value turns it on.
Examples
MASK:LOCK? might return :MASK:LOCK 1, indicating that the mask lock to
waveform mode is enabled.
MASK:MARgin:PERCent
Sets or returns the tolerance for the mask test. A positive value expands themask
and a negative margin shrinks the mask by the specified percentage.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:MARgin:PERCent <NR3>
MASK:MARgin:PERCent?
Related Commands
MASK:CUSTom
MASK:USER:WIDth
Arguments
<NR3> is a floating point value that ranges from -50.0 to +50.0. The default is 5.
Examples
MASK:MARGIN:PERCENT 25 sets the mask margin percentage to 25.
MASK:MARGIN:PERCENT? might return :MASK:MARGIN: PERCENT
1.00000000000E+001
, indicating that the mask margin is set to 10%.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-377