Commands Listed in Alphabetical Order
Arguments
INTERNal speci
fies to save waveforms using an internal format. The file name
should be specified with .ISF filename extension. These files can be recalled as
reference waveforms.
SPREADSheet specifies that waveform data is saved in a format that contains
comma delimited values. These waveform data files should be named using the
.CSV filename extension. Saving waveforms in .CSV format enables spreadsheet
programs to import the data.
Examples
SAVE:WAVEFORM:FILEFORMAT INTERNAL specifies that the internal .ISV file
format is the format specified for saved waveforms.
SAVE:WAVEFORM:FILEFORMAT? might return :SAVE:WAVEFORM: FILEFORMAT
SPREADSHEET
indicating that waveforms are saved using the comma-delimited
.CSV format, enabling them to be imported by spreadsheet programs.
SAVe:WAVEform:FILEFormat:RF_BB_IQ
This command specifies the file format for saving the RF baseband I & Q data.
The default format is TIQ. See the description of the SAVe:WAVEform command
for detailed information about these formats.
Group
Save and Recall
Syntax
SAVe:WAVEform:FILEFormat:RF_BB_IQ {TIQ|MATLAB}
SAVe:WAVEform:FILEFormat:RF_BB_IQ?
Arguments
TIQ specifies to use the TIQ file format for saving the RF baseband I & Q data.
MATLAB specifies to use the MATLAB file format for saving the RF baseband I
&Qdata.
Examples
SAVE:WAVEFORM:FILEFORMAT:RF_BB_IQ TIQ specifies the the TIQ file format
for saving the RF baseband I & Q data.
SAVE:WAVEFORM:FILEFORMAT:RF_BB_IQ? might return
:SAVE:WAVEFORM:FILEFORMAT MATLAB indicating that MATLAB is
the currently selected file format for saving the RF baseband I & Q data.
SAVe:WAVEform:GATIng
Specifies whether save waveform operations should save the entire waveform
(NONe) or a specified portion of the waveform.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-605

Table of Contents

Other manuals for Tektronix MDO4000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4000B Series and is the answer not in the manual?

Tektronix MDO4000B Series Specifications

General IconGeneral
BrandTektronix
ModelMDO4000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals