EasyManuals Logo

Tektronix TBS1032B User Manual

Tektronix TBS1032B
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Taking automatic
measurements
The oscilloscope can take automatic measurements of most displayed signals.
NOTE. If a question mark (?) appears in the Value readout, the signal is outside
the measurement range. Adjust the Vertical Scale knob (volts/division) of the
appropriate channel to decrease the sensitivity or change the horizontal Scale
setting (seconds/division).
To measure signal frequency, period, and peak-to-peak amplitude, rise time, and
positive width, follow these steps:
1. Push the Measure button to see the Measure Menu.
2. Push the channel 1 or the 2 button. The measure menu appears to the left.
3. Turn the Multipurpose knob to highlight the desired measurement. Push the
knob to select the desired measurement. .
The Value readout displays the measurement and updates.
4. Push the channel 1 or 2 button to select another measurement. You can
display up to six measurements on the screen at a time.
Measurem
ents
Period
Frequency
Peak-Peak
Minimum
Maximum
Mean
Cycle
Mean
Cursor
Mean
RMS
Cycle RMS
Cycle RMS
Rise Time
Measure
Gating
On / Off
Ch1
Ch2
Math
Application examples
TBS1000B and TBS1000B-EDU Series Oscilloscopes User Manual 31

Table of Contents

Other manuals for Tektronix TBS1032B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TBS1032B and is the answer not in the manual?

Tektronix TBS1032B Specifications

General IconGeneral
Bandwidth30 MHz
Channels2
Sample Rate1 GS/s
Record Length2.5 kpts
Timebase Range5 ns/div to 50 s/div
Display Resolution800 x 480
ConnectivityUSB 2.0
Input CouplingAC, DC, GND
InterfaceUSB
Power Supply100-240 VAC, 50/60 Hz
Display7 inch TFT color display
Vertical Sensitivity2 mV/div to 5 V/div
Trigger TypesEdge, Pulse, Video
Math FunctionsAdd, Subtract, Multiply, Divide
Input Impedance1 MΩ ± 2%
Maximum Input Voltage300 V (DC + peak AC)
Probe TypePassive