Warranted Characteristics
TDS 500B, 600B and TDS 700A Service Manual
1–17
Table 1–10: Warranted Characteristics — Signal Acquisition System (Cont.)
Name Description
A
n
al
o
g
Ba
n
d
w
id
t
h
,
D
C
-
50 Co
upled
and Bandwidth selection is FULL,
TDS B A
Volts/Div
520B, 540B, 724A,
744A Bandwidth
2
784A Bandwidth
2
TDS
500
B
/700
A
10 mV/div –
1 V/div
5 mV/div –
9.95 mV/div
2 mV/div –
4.98 mV/div
1 mV/div –
1.99 mV/div
DC – 500 MHz
DC – 500 MHz
DC – 500 MHz
DC – 450 MHz
DC – 1 GHz
DC – 750 MHz
DC – 600 MHz
DC – 500 MHz
Crosstalk (Channel Isolation) 100:1 at 100 MHz and 30:1 at the rated bandwidth for the channel’s Volt/Div setting,
for any two channels having equal Volts/Div settings
Delay Between Channels, Full
Bandwidth
TDS 600B: 100 ps for any two channels with equal Volts/Div and Coupling settings and
both channels’ deskew values set to 0
TDS 500B/700A: 50 ps for any two channels with equal Volts/Div and Coupling settings
Input Impedance, DC–1 M Coupled 1 M ±0.5% in parallel with 10 pF ±3 pF
Input Impedance, DC–50 Coupled
50 ±1% with VSWR 1.3:1 from DC – 500 MHz, 1.5:1 from 500 MHz – 1 GHz
Input Voltage, Maximum, DC–1 M ,
AC–1 M , or GND Coupled
TDS 600B: ±400 V (DC + peak AC); derate at 20 dB/decade above 1 MHz
TDS 500B/700A: ±300 V (DC + peak AC), 400 V peak;
derate at 20 dB/decade above 1 MHz, category II
Input Voltage, Maximum, DC-50 or
AC–50 Coupled
5 V
RMS
, with peaks ±30 V
Lower Frequency Limit, AC Coupled 10 Hz when AC–1 M Coupled; 200 kHz when AC–50 Coupled
3
1
Net Offset = Offset – (Position × Volts/Div). Net Offset is the nominal voltage level at the oscilloscope input that
corresponds to the center of the A-D converters dynamic range. Offset Accuracy is the accuracy of this voltage level.
2
The limits given are for the ambient temperature range of 0_C to +30_C. Reduce the upper bandwidth frequencies by
5 MHz for the TDS 600B or by 2.5 MHz for the TDS 500B/700A for each _C above +30_C.
3
The AC Coupled Lower Frequency Limits are reduced by a factor of 10 when 10X passive probes are used.
Table 1–11: Warranted Characteristics — Time Base System
Name Description
Accuracy, Long Term Sample Rate and
Delay Time
TDS 600B: ±100 ppm over any 1 ms interval
TDS 500B/700A: ±25 ppm over any 1 ms interval

Table of Contents

Other manuals for Tektronix TDS 700A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS 700A and is the answer not in the manual?

Tektronix TDS 700A Specifications

General IconGeneral
BrandTektronix
ModelTDS 700A
CategoryTest Equipment
LanguageEnglish

Related product manuals