EasyManuals Logo
Home>Tektronix>Test Equipment>TDS3012C

Tektronix TDS3012C User Manual

Tektronix TDS3012C
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
Appendix A: Specications
Inputs
Measured on one channel, with test signal applied to another
channel, and with the same scale and coupling settings on
each chann el
Frequency range
Crosstalk
100 MHz 100:1
300 MHz 50:1
Channel
to channel
crosstalk,
typical
500 MHz 30:1
Differential
delay,
typical
100 ps between any two channels with the same scale and
coupling settings
1
For denitions, refer to C ompliance Information.(Seepagexi,Compliance information.)
TDS3000C Series O scilloscope User Manual 151

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS3012C and is the answer not in the manual?

Tektronix TDS3012C Specifications

General IconGeneral
BrandTektronix
ModelTDS3012C
CategoryTest Equipment
LanguageEnglish

Related product manuals