Output OUT 1 is active high (provides power
when active). The connected load must be
connected between GND and OUT 1. Loads
requiring more than 0.5 A must be controlled
with relays. The power provided by the
outputs complies with the supply voltage.
To use inputs they must be connected to
ground. With the inputs of TomTom LINK, up
to five inputs (on/off) can be recorded. It is
possible, for instance, to monitor digital
events like the opening of a loading tail-lift or
the switching of aggregates and to transfer
corresponding status messages.
Caution
Do not switch safety relevant vehicle functions.