FuelSystem
Maintenance
FuelSystem
FuelLinesandConnections
ServiceInterval:Every400hours/Yearly(whichever
comesrst)
Every1,000hours/Every2years
(whichevercomesrst)
Checklinesandconnectionsevery400hoursoryearly,
whichevercomesrst.Inspectfordeterioration,
damage,orlooseconnections.
FuelFilter
ServiceInterval:Beforeeachuseordaily
Every400hours
Drainwaterorothercontaminantsfromfuellter/water
separatordailybylooseningdrainplug(Figure51)on
ltercanister.Tightenplugafterdraining.
1.Raisebed(ifsoequipped)andplacesafetysupport
onextendedliftcylindertoholdupbed.
2.Placeacleancontainerunderfuellters.
Figure51
1.Fuellter
3.LoosenR–clampssecuringltertoframe.
4.Removeclampsecuringfuelltertofuellines.
5.Installnewfuelltertofuellineswithclamps
previouslyremoved.Filtermustbemountedso
arrowpointstowardcarburetor.
ElectricalSystem
Maintenance
Fuses
Thefusesforthemachine’selectricalsystemarelocated
underthecenterofthedashpanel.
Figure52
1.Fuses
Figure53