18
Watering Delay
™
Controller operation can be suspended from 1 to 4 days by pressing the
Watering Delay Key. Each time the key is pressed, operation is
suspended for one day. The Watering Delay Indicator will flash one,
two, three, or four times (repeatedly) signifying the number of days remaining
until controller operation resumes. Example: If you wish to suspend watering for
the rest of today and tomorrow, press key twice.
Note: The controller recognizes the end of a day at 12:00 a.m. (midnight).
To cancel Watering Delay at any time, simply press and hold the Watering
Delay Key for 5 seconds. Controller will resume operation.
Seasonal Adjust Control
™
Changes in weather often require a change in sprinkler run time to prevent
under or over watering. A unique feature of the Vision II, called Seasonal
Adjust Control, enables station run times to be increased or decreased
simultaneously by the movement of a single control.
Sliding the control from center position (100%) toward minus (–) reduces run
time in 5% increments down to 25% of setting. Sliding the control toward
plus (+) increases run time in 5% increments up to 200%. To reduce the
possibility of water run off, any setting above 100% automatically increases
the set run time, calculates half of the increased value, and operates the
watering cycle twice.
Example: A station has a set run time of 20 minutes. The Seasonal Adjust
Control is set at 150% which increases the run time value to 30 minutes. The
actual run time of the station will be 15 minutes per each of two concurrent
watering cycles.
Note: Station run time will be displayed at 100% value regardless of
Seasonal Adjust Control setting. Actual run time will appear on display
and count down while station is operating.
■ To Change Setting From 100%:
❑ Slide Seasonal Adjust Control
toward (+) or (–). Percentage of
increase or decrease appears on
display for 5 seconds after control
is moved. (Example shown: 65%.)