SERIES OVERVIEW
Page 5
710-02887-00A
TMC7 Series
3.2 Dimensions & Weights
TMC7-007 ~ TMC7-030 (2.4kg)
98 (3.86) 165 (6.50)
82 (3.23)
C
23
(0.9)
23
(0.9)
Ready
Run
TOSHIBA INTERNATIONAL CORPORATION PTY LTD - AUSTRALIA
SOFT STARTER
C1 R33R34C2 R43R4 4 02 01 A2 A1 A3
Motor
Ther mi s to r
Input N.O. N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
StartStop
RESET
Aux
Relay
Phase
Rotation
TRIP CODES
Ready
x 1. Power
Circuit
x 2. Excess
Start Time
x 3. Motor
Overload
x 4. Motor
Thermis tor
x 5. Cu rrent
Imbalance
x 6. Supply
Frequency
x 7. Phase
Rotation
x 8. Comms
Failur e
Motor FLC
(% TMC7 FLC)
Current Ram p
(%FLC/Ramp Time)
OFF
5s
15s
15
2s
5s
5s
2s
2s
15
70%
80%
60% 90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%300%
250%
Motor Trip
Class
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC
7
SERIE S
Soft S top
(Seconds)
No
Soft Stop
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC7-037 ~ TMC7-055 (4.3kg)
145 (5.71) 193 (7.60)
37
(1.46)
37
(1.46)
124 (4.88)
Ready
Run
TOSHIBA INTERNATIONAL CORPORATION PTY LTD - A USTRAL IA
SOFT STARTER
C1 R33R34C2 R43R44 02 01 A2 A1 A3
Motor
Thermistor
Input N.O. N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
StartStop
RESET
Aux
Relay
Phase
Rota tion
TRIP C ODES
Ready
x 1. Power
Circ ui t
x 2. Excess
Sta rt T ime
x 3. Motor
Overload
x 4. Motor
Thermistor
x 5. Current
Imb ala nce
x 6. Supply
Frequen cy
x 7. Phase
Rotation
x 8. Comms
Fai lur e
Motor FLC
(% TMC7 FLC)
Current Ramp
(%FLC/Ramp Time)
OFF
5s
15s
15
2s
5s
5s
2s
2s
15
70%
80%
60% 90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%300%
250%
Motor T rip
Clas s
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC
7
SERIES
Soft Stop
(Seconds)
No
Soft Stop
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC7-075 ~ TMC7-110 (6.8kg)
202 (7.95) 214 (8.43)
160 (6.30)
51
(2.0)
51
(2.0)
Ready
Run
TOSHIBA INTERNATIONAL CORPORATION PTY LTD - AUSTRALIA
SOFT STARTER
C1 R 33 R34C2 R43 R44 02
01 A2 A1 A3
Motor
Thermistor
Input N.O. N.O.
Relay Outputs
110 - 240VAC
Control Supply
380 - 440VAC or
StartStop
RESET
Aux
Relay
Phase
Rotation
TRIP CODES
Ready
x 1. Power
Circuit
x 2. Exce ss
Start Time
x 3. Mo tor
Overload
x 4. Mo tor
Thermistor
x 5. Current
Imbalance
x 6. Supply
Frequency
x 7. Phase
Rotation
x 8. Comms
Failure
Moto r FLC
(% TMC7 FLC)
Current Ramp
(%FLC/Ramp Time )
OFF
5s
15s
15
2s
5s
5s
2s
2s
15
70%
80%
60% 90%
100%
50%
Current Limit
(% Motor FLC)
350%
450%
400%300%
250%
Motor Trip
Class
OFF
2
4
6
8
10
12
14
16
20
Excess
Start Time
OFF
2s
4s
6s
8s
10s
12s
14s
16s
20s
TMC
7
SERIES
Soft Stop
(Seconds)
No
Soft Stop
2s
4s
6s
8s
10s
12s
14s
16s
20s