6.26 Stall prevention function
6.26.1 Power running stall continuous trip detection time
 : Power running stall continuous trip detection time
Function
A function for preventing lifting gear from failing accidentally. If the stall prevention function is activated in
succession, the inverter judges that the motor has stalled and trips.
[Parameter setting]
Title Function Adjustment range Default setting
 Power running stall continuous trip detection time ~ sec. 
Time [s]
Output frequency [Hz]
Time [s]
Output current [%]

less than



” trip
6.26.2 Regenerative braking stall prevention mode selection
 : Regenerative braking stall prevention mode selection
Function
A function for preventing lifting gear from stopping in the wrong position. Only the function of preventing a
stall by maintaining the current and voltage constant during regenerative braking (deceleration stop) is
deactivated.
[Parameter setting]
Title Function Adjustment range Default setting

Regenerative braking stall prevention
mode selection
:Stall during regenerative braking
:Not stall during regenerative braking
6.27 Current and speed control adjustment
6.27.1 Current and speed control gain
: Current and speed control gain
For details, refer to Instruction Manual (E6581333) specified in Section 6.42.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS1
CategoryInverter
LanguageEnglish

Related product manuals