3) S-pattern acceleration/deceleration 2
Select this pattern to obtain slow acceleration in a demagnetizing region with a small motor acceleration torque.
This pattern is suitable for high-speed spindle operation.
Set frequency

Actual acceleration time
Output frequency [Hz]
Time [s]
0
Base frequency
Set frequency

Actual deceleration time
Output frequency [Hz]
Time [s]
0
Base frequency
Maximum frequency

Maximum frequency

6.31 Pattern operation
 : Pattern operation selection
 : Pattern operation mode
 ,  : Number of repetitions of pattern group 1, 2
 ~  : Pattern group 1 selection 1~8
 ~  : Pattern group 2 selection 1~8
 ~  : Speed 1~15 operation time
Function
These parameters allow you to combine a maximum of 30 operation frequencies, operation time and
acceleration/deceleration time (15 combinations of parameters x 2 patterns) for automatic pattern operation
by means of the terminal board.
[Parameter setting]
Title Function Adjustment range Default setting
 Pattern operation selection
:Disabled,
:Enabled (setting in seconds)
:Enabled (setting in minutes)

 Pattern operation mode
:Pattern operation reset when
system stops operation
:Pattern operation continued
even after system stops
operation

 Number of repetitions of pattern group 1 ~, :Successive 
~ Pattern group 1 selection 1~8 :Skip, ~ 
 Number of repetitions of pattern group 2 ~, :Successive 
~ Pattern group 2 selection 1~8 :Skip, ~ 
~ Speed 1~15 operation time
~ (The unit depends
on the setting of .)
:Infinite (depends on the
stop trigger entered)

* Forward/reverse, acc/dec time 1, 2, V/f 1, 2 can be set with ~ (Preset speed operation frequency
1~15 operation modes).
For details, refer to Section 5.12.
Note: When the function of auto-restart is active, the time spent for speed search is added to the operation time set
for pattern operation. Consequently, the effective operation time sometimes becomes shorter than the settled
operation time.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS1
CategoryInverter
LanguageEnglish

Related product manuals