BAS-SVX078E-EN
19
Settings
Table 1. Group 1 standard settings
Menu Item Options [Default] Description
Cooling Type None [Cooling Only]/ Heat Pump Select the type of outdoor unit installed
Cooling Stages [Single Stage], Two Stage Select the number of outdoor unit stages.
Compressor Type
Single Compressor Two Stage,
[Two Compressor Two Stage]
Select the compressor type for multi-stage outdoor
units.
Heating Type [Gas/Oil], Electric, Hydronic Select the type of indoor unit installed.
Heat Stages [Single Stage], Two Stage, Three Stage Select the number of heat stages
Blower Type
Variable, [Non-Variable]
(a)
Select the blower type [Constant Torque motors are
considered non-variable speed]
(a)
SOV Operation
[with Cooling Call], with Heating Call Select which mode of operation energizes the
switch-over valve.
(a)
Variable speed applies only to supported Trane residential equipment
Table 2. Group 2 equipment settings
Menu Item Options [Default] Description
Compressor Cooling Cycles per Hour
2 to 6 Cph [3] Select the number of cycles per hour during cooling
operation.
1st Stage Compressor Cooling Cycles Per Hour
2 to 6 Cph [3] Select the cycles per hour during 1st stage cooling
operation
2nd Stage Compressor Cooling Cycles Per Hour
2 to 6 Cph [3] Select the number of cycles per hour during 2nd
stage cooling operation
Compressor Heating Cycles Per Hour
2 to 6 Cph [3] Select number of cycles per hour during
compressor heating operation.
1st Stage Compressor Heating Cycles Per Hour 2 to 6 Cph [3] Select the minimum runtime [MRT] of stage 1 heat
2nd Stage Compressor heating Cycles Per Hour 2 to 6 Cph [5] Select the minimum runtime [MRT] of stage 2 heat
Heating Cycles Per Hour
2 to 6 Cph [5] Select the number of cycles per hour during heat
operation
1st Stage Heat Cycles Per Hour
2 to 6 Cph [5] Select the number of cycles per hour during 1st
stage heat operation
2nd Stage Heat Cycles Per Hour
2 to 6 Cph [5] Select the number of cycles per hour during 2nd
stage heat operation
3rd Stage Heat Cycles Per Hour
2 to 6 Cph [5] Select the number of cycles per hour during 3rd
stage heat operation
System Setup

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Pivot BAYSTAT814 Series and is the answer not in the manual?

Trane Pivot BAYSTAT814 Series Specifications

General IconGeneral
BrandTrane
ModelPivot BAYSTAT814 Series
CategoryThermostat
LanguageEnglish

Related product manuals