Replacement of the fuses is seldom required. Burning
of a fuse always results from improper operation.
50
Model UT803: OPERATING MANUAL
Fuse 4:It is located at the PCB. Remove the fuse
by gently prying one end loose, then take out the
fuse from its bracket. Then install the replacement
fuse
Install ONLY replacement fuses with the identical
type and specification as follows and make sure the
fuse is fixed firmly in the bracket.
Fuse 1: 200mA, 250V, fast type, 5x20mm (AC220V)
Fuse 2: 10A, 250V, fast type, 5x20 mm (A)
Fuse 3: 500mA, 250V, fast type, 5x20 mm (µA, mA)
Fuse 4: 200mA, 250V, fast type, 5x20 mm (hFE)
3.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT803 and is the answer not in the manual?

UNI-T UT803 Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
Frequency range6 - 60000 kHz
AC current range0.06 - 10 A
DC voltage range0.6 - 1000 V
Capacitance range6 - 6000 nF
Statistic functionMaximum, Minimum
Resolution (frequency)100000 Hz
Resolution (AC current)6000 µA
Basic accuracy (frequency)±(0.1%+3)
Basic accuracy (DC current)±(0.5%+3)
Basic accuracy (DC voltage)±(0.3%+2)
Basic accuracy (resistance)±(0.5%+2)
Basic accuracy (capacitance)±(2%+5)
Temperature measurement range-40 - 1000 °C
Dimensions (WxDxH)310 x 240 x 105 mm
Battery voltage1.5 V
Weight and Dimensions IconWeight and Dimensions
Weight2400 g