13
DS1083-180
5.4. PARAMETER ASSOCIATED TO PROGRAMMING LED (1)
COLOUR
Parametertobecongured LED (1) Parametervalue LED state (4)
Parameter1:
doorunittype LED C: Green
Main LEDso
Secondary LEDsonsteady
Parameter2:
door unit ID LED C: Red
Address 0 LEDso
Address 1 LEDsonsteady
Parameter3: door opener LED B: Orange
Privacy LEDso
Free LEDsonsteady
Parameter4: callbuttonenabling LED A: Green
No button enabled LEDso
Onlythecallingbutton(7)
is enabled
LEDsonsteady
Bothbuttonsareenabled LEDsonblinking
Parameter 5:
(*)
callbuttonassociation
withswitchboardcall
LED A: Red
Notactive LEDso
Arm LEDsonsteady
(*) Function only possible if door unit is congured as main unit.
5.5. DEFAULT CONFIGURATION
Parameter Function Default
Parameter1 Doorunittype Main
Parameter2 Door unit ID Address 0
Parameter3 Door opener Privacy
Parameter4 Call button enabling Bothbuttonsenabled
Parameter5 Callbuttonassociationwithswitchboardcall Notactive
6. HOW TO RESET DEFAULT SETTINGS
Pressthe PROGRAMbutton (10)briey togo toconguration state.The LEDs(1) willblink duringthis
step.
ThenholdtheBUTTON(7)pressedforlongerthan10seconds.
The door unit will generate two 2-second long beeps and all parameters will be reset before exiting
congurationstate.
7. ADVANCED CONFIGURATION (WITH WiFi CONFIGURATION)
Preparethedevice asWiFi accesspointfor advancedconguration oftheaudio-video doorunits Ref.
1083/48andaudiodoorunitsRed.1083/38.Tostartthistypeofconguration,followthatshowninthe
instructionbookletontheUrmetwebsite,whichcanbedownloadedbyframingtheQRCodeshownbelow
withthecameraofyoursmartphoneortablet:
Audio-videodoorunitRef.1083/48 AudiodoorunitRef.1083/38
http://qrcode.urmet.com/default.aspx? http://qrcode.urmet.com/default.aspx?
prodUrmet=142027&lingua=en prodUrmet=142025&lingua=en