Fig. 11
KEY
1 Softener
2 Mesh filter
3 Drain Ø 50 mm
CAUTION
RISK OF SHORT CIRCUITS
Prior to connecting the machine to the electrical
mains, assess that the voltage shown on the
machine’s data plate corresponds with that of
the mains.
If it does not, carry out the connections on the
basis of the available electrical line, as follows:
IRUV 380 / 3 phases voltage + Neutral:
Fig. 13
Fig. 14
KEY
1 Black
2 Grey
3 Brown
The machine must always be protected by an
automatic omnipolar switch of suitable
power with contact openings of equal dis-
tance or more than 3mm.
Victoria Arduino is not liable for any damage
to people or objects due to not observing
current security measures.
Avoid throttling in the connecting tubes.
Assess that the drain pipe (3) is able to
eliminate waste.
WARNING
IRUV 230 / monophase voltage
4 Blue
5 Yellow-green
In this way impurities like sand, particles of
calcium, rust etc will not damage the delicate
graphite surfaces and durability will be guaran-
teed.
Following these operations, connect the plumb-
ing systems as illustrated in the following figure.
NOTE: In case of use where service is continu-
ous, make the above changes at least
once a week.
4.2 WATER
SPECIFICATIONS
Monitoring of water recipe to keep it within
required levels and maintenance of filtration
system is the user's responsibility.
Failing to meet and maintain water at the follow-
ing levels will void the entire warranty:
WRWDOKDUGQHVVSSPSDUWVSHUPLOOLRQ
ZDWHU OLQH SUHVVXUH EHWZHHQ ± EDU DQG
water to be cold
PLQIORZUDWHOKU
ILOWUDWLRQOHYHOEHORZPLFURQ
WGVWRWDOGLVVROYHGVROLGVOHYHOEHWZHHQ
±SSP
DONDOLQLW\OHYHOEHWZHHQ±SSP
FKORULQHOHYHOOHVVWKDQPJO
3KOHYHOEHWZHHQDQG
4.3 ELECTRICITY
SPECIFICATIONS
4.1 CABLE STRIP
COVERING
(optional)
Once the machine has been levelled and con-
nected to the power and water mains, use the
cable strips (optional) to cover up the wiring, as
shown in the figure.
Fig. 12
NOTE: At the start of the day’s activities and in
any case, if there are any pauses of
more than 8 hours, then it is necessary
to change 100% of the water in the cir-
cuits, using the relevant dispensers.
2
3
1