Portable Generator Repair G 2.5A
wc_tx000207gb.fm 45
5.18 Periodic Maintenance Schedule
5.19 Engine Service
Normal servicing of the engine such as cleaning the air cleaner,
sediment cup, carburetor adjustments, auto idle speed and engine
speed can be located in the Operator’s manual. In depth engine
service should be performed by qualified personnel or by the nearest
Honda dealer.
Daily
before
starting
After
first
20 hrs.
Every
50
hrs.
Every
100
hrs.
Every
300
hrs.
Check fuel level.
Check engine oil level.
Inspect air filter. Replace as needed.
Check and tighten external hardware.
Clean air cleaner elements.*
Inspect shockmounts for damage.
Change engine oil.* ••
Clean sediment cup.*
Check and clean spark plug.
Check and adjust valve clearance.
Clean fuel tank.*
Check condition of fuel line. Replace
when necessary.
*Service more frequently in dusty conditions.