23
Operations
Emptying and Cleaning Tanks
1. Park the machine next to a floor drain. Drain hoses
are at the front of the machine.
2. Turn the machine power off.
Recovery Tank
1. Open the recovery tank lid. Pull the recovery drain
hose from the mounting bracket. Open cap, then
lower hose in direction of the drain. Do not stand in
front of end of hose. Recovered solution will come
out with force.
2. Flush the recovery tank out with clean water. Do
not use water hotter than 140°F (60°C) to clean
tank. Damage may occur.
3. Clean debris bin.
4. Clean off the float shut-off system and inspect for
free movement of float.
5. Replace the drain hose cap and secure drain hose.
6. If machine is to be stored, leave the recovery tank
lid propped open.
Solution Tank
1. Remove the recovery tank lid.
2. Pull the solution drain hose from its mounting
pocket. Unscrew the cap, then lower hose in direc-
tion of drain.
3. Remove the solution tank cap.
4. Flush the solution tank out with clean water and
run several gallons of clean water through sys-
tems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
5. If machine is to be stored, leave solution cap off.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
Solution Drain
Hose
Recovery Drain
Hose
Recovery Tank
Lid
86372820 Chariot 3 iExtract 26 Duo